An inherited configuration, explained line by line.
Paste a configuration nobody on the team wrote. ARIA explains each rule in plain language and suggests improvements, without touching the device.
03:12
One engineer on call, hundreds of devices, and a ticket that will not wait for the morning.
Diagnose
12% loss, spikes to 310 mshop 3 core-sw-02 at 340 mscore uplink at 96% utilisationProposed fix
Nothing has run yet.
Template
queue-limit-customer
Apply the template queue-limit-customer: limit site-0847 to 50M down and 20M up.
Values
queue-limit-customer customer=site-0847 max_download=50M max_upload=20M
Every command is classified as a read or a write, by a classifier validated on more than 1,600 real commands.
Free-form writes stay inside the permitted namespaces. 10 are never writable.
When a template is used, the change must match the vetted template it came from, or it never reaches approval.
Writes per session are capped.
Human in the loop
queue-limit-customer customer=site-0847 max_download=50M max_upload=20MApply the template queue-limit-customer: limit site-0847 to 50M down and 20M up.
Confirm? [y/N]
Approved. The change is sent to the device.
Rejected. Nothing ran.
Single use. Expires in 5 minutes.
Bound to this command, user, session and device.
On yes, an audit record is written before the device is touched.
queue-limit-customer Pendingqueue-limit-customer Pendingqueue-limit-customer Successcustomer=site-0847 max_download=50M max_upload=20M80,000+ devices through OptiWize
In practice
Paste a configuration nobody on the team wrote. ARIA explains each rule in plain language and suggests improvements, without touching the device.
ARIA runs reachability, path and speed checks and adds an overall assessment, so every ticket starts from the same picture.
When the change did not match the template it came from, the server stopped it before approval was requested. The person only saw the real values.
A device comment says to ignore previous instructions. ARIA treats it as untrusted data, and no write runs until a person approves the real command on screen.
Pricing
EUR 49 per user per month
Fleet inventory, reads, chat, ping, path trace and suggestions. No live writes.
EUR 99 per user per month
Speed test, full troubleshoot, device snapshot analysis, templates and approved writes.
EUR 199 per user per month
Everything in Pro, plus model choice, bring your own key and more capacity.
FAQ
MikroTik today. TR-069 and TR-369 compatible devices are on the roadmap.
No. Reads need no approval. Every write waits for a person to approve the exact change, and an audit record is written before the device is touched.
Base EUR 49, Pro EUR 99 and Pro Max EUR 199, per user per month. Live writes need Pro or Pro Max.
Request a demo